XN-1000
Sysmex´s flagship analyser
- 100 samples/h
- Sampler capacity 5 racks
- Choose diagnostic APPs as needed
- Short turnaround times
- Networking and remote services capabilities
This is a standalone, benchtop instrument. In its Rerun & Reflex configuration, the XN-1000 offers reproducible result quality in the shortest possible time. By automatically reanalysing samples for which results are considered unreliable, it significantly reduces manual interventions and frees up time and resources. With no compromise on turnaround time. Reagent management is simple too – if you want we can integrate your reagents in an analyser wagon.
The XN-1000 can be equipped with all the available diagnostic applications. Depending on what is installed, the XN Rerun & Reflex performs a range of rule-based tests. The samples in question are fed into extended measurement automatically. Extended measurement is only performed if it adds additional diagnostic value.
While the XN-1000 is a standalone system, optional software can still make it uniquely flexible. It can be networked with other XN concepts at other locations. Think of individual systems for measuring body fluids on neurology wards. Or transfusion centres. And thanks to our remote services, we can together define levels of support quality, guaranteed service response times and ensure maximum system uptime.
Measurement principles | WBC DIFF/RET/PLT-F/WPC: Fluorescence Flow Cytometry RBC/PLT: Hydrodynamically focussed impedance HGB: Cyanide-free SLS haemoglobin |
Aspiration volume | 88 µL in whole blood (WB) mode and body fluid (BF) mode |
Throughput | up to 100 samples/h |
Quality control material | XN Check (three levels) and XN Check BF (two levels) |
Parameters | XN-CBC (always with NRBC) & XN-DIFF (always with IG) Whole Blood WBC, NRBC%, NRBC#, RBC, HGB, HCT, MCV, MCH, MCHC, PLT, RDW-SD, RDW-CV, MicroR%, MacroR%, PDW, MPV, P-LCR, PCT, NEUT%, NEUT#, LYMPH%, LYMPH#, MONO%, MONO#, EO%, EO#, BASO%, BASO#, IG%, IG# With RET (optional) RET%, RET#, IRF, LFR, MFR, HFR, RET-He, RBC-He, Delta-He, HYPO-He%, HYPER-He%, PLT-O With PLT-F (optional) PLT-F, IPF, IPF# With WPC (optional) Extended Inflammation Parameters licence: NEUT-GI, NEUT-RI, RE-LYMP%, RE-LYMP#, AS-LYMP%, AS-LYMP# XN Stem Cells licence HPC%, HPC# Body Fluids with XN-BF WBC-BF, RBC-BF, MN%, MN#, PMN%, PMN#, TC-BF# (optional) |
Configurations | XN-1000 [DIFF] XN-1000 [WPC] |